ATOM Max Dental & Diagnostic Head Phantom

The Model 711-HN provides a consistent tool for researchers, clinicians and technologists. It is ideal for determining optimum system settings, commissioning new equipment, monitoring system performance and training in dental X-ray, panoramic X-ray, CT and cone beam CT procedures.


The phantom includes an adjustable stand for positioning within a cone beam CT or panoramic X-ray system. The jaw of the phantom is slightly opened and front teeth are vertically aligned to replicate correct positioning with a bite guide. Please note that an actual bite guide cannot be positioned in this product.


The phantom is constructed of proprietary tissue equivalent materials. ATOM®Max is made of tissue simulating resins that mimic the X-ray attenuation properties of human tissue for both CT and therapy energy ranges (50 keV-25 MeV). The Model 711-HN approximates the average male human head in both size and structure. The phantom includes detailed 3D anthropomorphic anatomy including brain, bone, larynx, trachea, sinus, nasal cavities and teeth. The bones contain both cortical and trabecular separation. The teeth include distinct dentine, enamel and root structure including the nerve. The sinus cavities are fully open.


Features and Benefits

  • Includes detailed anatomical features
  • Frankfurt plane identified to ensure proper alignment
  • Tissue Equivalent from 50 keV to 25 MeV
  • Positioning stand with six degrees-of-freedom


Sample Screenshots







Technical Specifications


  • Overall Size (phantom only): 7.1" x 8.8" x 10.6"
  • Phantom Weight: 14 lbs.
  • Stand Weight: 7 lbs.
  • Shipping Weight: 31 lbs.
  • Phantom Materials: Epoxy Resin

Materials Included

  • (1) ATOM®MAX Dental & Diagnostic Head Phantom
  • (1) Positioning Stand w/ soft sided carry case
  • (1) Phantom carry case
  • User Manual

711-HN头部及诊断模体


11-HN模型为研究人员、临床医生和技术人员提供了一致的工具。它是确定系统设置,调试新设备,监测系统性能和牙科x射线,全景x射线,CT和锥形束CT程序培训的理想选择。

该体模包括一个可调支架,用于在锥形束CT或全景x射线系统内定位。幻肢的下颚微微张开,前牙垂直排列,以复制正确的定位与咬合指南。请注意,实际的叮咬指南不能定位在这个产品。

幻影是由专有的组织等效材料构成的。ATOM®Max是由组织模拟树脂制成,模拟人体组织在CT和治疗能量范围(50 kev - 25mev)下的x射线衰减特性。711-HN模型在大小和结构上都接近男性头部的平均水平。幻影包括详细的三维拟人解剖,包括大脑、骨骼、喉部、气管、鼻窦、鼻腔和牙齿。骨骼包含皮层和小梁的分离。牙齿包括独特的牙本质、牙釉质和包括神经在内的根结构。窦腔完全开放。

特性和好处

包括详细的解剖特征

法兰克福飞机确认,以确保正确的路线

组织当量为50kev ~ 25mev

六自由度定位架

示例截图

技术规格

整体尺寸(仅限幻影):7.1" x 8.8" x 10.6"

幻影重量:14磅。

站立重量:7磅。

装运重量:31磅。

模体材料:环氧树脂

材料包括

(1) ATOM®MAX牙科诊断头体模

(1)定位架w/软边置箱

(1)幻影机箱

用户手册


更多 美国CIRS公司711-HN头部及诊断模体 价格、说明、厂家,请关注3618医疗器械网
暂无内容,请联系商家咨询详情
  • 代理/采购留言
标注有 * 的地方是必填项,请按要求填写,不要提交毫无意义的内容,谢谢合作!
需求选择:  我要代理 我要采购 * 身份选择: 公司代理 个人代理 医院采购 个人采购 * 留言标题: 美国CIRS公司711-HN头部及诊断模体 希望代理区域: * 联系人姓名: * 联系电话:
*
电子邮箱: 内容:   

* 温馨提示:请仔细阅读产品说明书或在医务、专业人员指导下购买和使用,禁忌内容或者注意事项详见说明书。

公司名称:北京华贺技术北京有限公司

营业执照证号:91110105355230542A

访问量:8690